CPSC official recall · 02231

CPSC, Fluke Corp. Announce Recall of Digital Multimeters

召回日期:2002-08-19官方最后发布:2025-10-08适用地区:美国
重要:以下安全事实保留 CPSC 官方英文原文,避免翻译改变含义。请通过右侧官方公告确认行动要求。

危险说明 Hazard

  • The recalled units can take longer than normal, up to 18 seconds, to display readings of AC voltages above 500 volts. Users can misinterpret the delayed reading to mean that high voltage is not present. If high voltage is present, users could be exposed to a risk of shock, electrocution, and thermal burns.

受影响产品

Fluke Digital Multimeters
Units:About 40,000

官方描述 Description

Multimeters are used to measure voltage, resistance and current. The recalled Fluke digital multimeters measure up to 1,000 volts alternating current (VAC) and direct current (VDC). "Fluke" and "175", "177" or "179" are written on the front of the unit. The tester body is yellow and black, and measures about 7.25 inches long by 3.5 inches wide. Recalled units have a serial number below 79000000. The serial number is written on the back of the instrument, under the hinged stand.

事故与伤害 Incidents / Injuries

  • Fluke has received four reports from Canada and Australia, in which users experienced a delayed response, while measuring high voltage, though no injuries were reported.

官方补救措施 Remedy

  • Consumers should stop using these testers immediately and contact Fluke for information on returning the recalled unit for a free repair.

消费者联系信息

Consumers should call Fluke at (800) 260-4819 between 8 a.m. and 7 p.m. ET Monday through Friday or at the Fluke website www.fluke.com/170recall

相关企业

制造商:Fluke Corp., of Everett, Wash.

零售商:Home and hardware stores and industrial distributors nationwide sold these testers, from January 2001 through October 2001, for between $170 and $215.