CPSC, Popeil Inventions Inc. Announce Recall of Heating Elements from Electric Rotisseries
危险说明 Hazard
- Certain units have been found to leak current from the heating element, posing a risk of electric shock.
受影响产品
官方描述 Description
These model number 4000 Showtime Rotisseries, manufactured in October 1999, have a serial number beginning with ST-AAKa, located on the back, near the bottom of the units. "Ronco Showtime BBQ" is written on the front glass and the model number is printed on the back.
事故与伤害 Incidents / Injuries
- The firm has received reports from 17 consumers, some of whom allegedly have suffered electric shocks while using these rotisseries. No serious injuries have been reported.
官方补救措施 Remedy
- Repair to the Model 4000 Showtime Rotisseries bearing serial numbers beginning with ST-AAKa is necessary to assure continued safe operation. To receive the free repair, that includes the cost of shipping, contact Popeil Inventions Inc. Popeil Inventions Inc. was able to notify all customers by direct mail and through notice posted on its web site.
消费者联系信息
To receive the free repair, that includes the cost of shipping, call Popeil Inventions Inc. toll-free at (800) 274-7417 between 8 a.m. and 5:00 p.m. PT Monday through Friday, or go to the firm's web site at www.ronco.com Popeil Inventions Inc. was able to notify all customers by direct mail and through notice posted on its web site.
相关企业
制造商:Popeil Inventions Inc., of Chatsworth, Calif.
零售商:Television infomercials and web sites sold these rotisseries, manufactured in October 1999, nationwide from November 1999 through May 2000.