CPSC official recall · 04534

CPSC, GE Security, Inc. Announce Recall of Carbon Monoxide Alarms

召回日期:2004-02-12官方最后发布:2025-04-02适用地区:美国
重要:以下安全事实保留 CPSC 官方英文原文,避免翻译改变含义。请通过右侧官方公告确认行动要求。

危险说明 Hazard

  • The recalled units fail to detect carbon monoxide after 1 year of operation, due to an internal software error. These CO alarms do not provide an "end of life" signal or other indication of inoperability, even if the test button is depressed.

受影响产品

Carbon Monoxide (CO) Alarms
Units:About 74,000

官方描述 Description

These ESL SafeAir 240-COE Carbon Monoxide alarms are hard-wired and require professional installation. The white, rectangular units are about 6 inches long and 2.75 inches high. "CARBON MONOXIDE ALARM" and "DO NOT PAINT" are written on the front of the units. "240-Coe, "SENTROL," (a former name of the company) and the date code are written on the back. The date code is a four-digit number ending with a "T." The four digits denote the year and week of manufacture. For example, the date code "0045T" refers to a unit that was manufactured in the 45th week of 2000. Only units with date codes 0045T (November 2000) through 0235T (August 2002) are included in the recall.

事故与伤害 Incidents / Injuries

  • GE Security has received one report that the CO detector did not operate properly in the presence of CO. No injuries have been reported.

官方补救措施 Remedy

  • Consumers should contact their system installer or service provider to arrange for the free installation of a replacement CO alarm.

消费者联系信息

Call UTC Fire and Security (formerly GE Security) at 855-286-8889 option 2 between 8am and 8pm ET Monday through Friday.

相关企业

制造商:GE Security, Inc., (GE Security) of Tualatin, Ore.

制造国家/地区:China

零售商:Distributors, dealers and installers of security systems nationwide, from November 2000 through October 2003, for about $49.