CPSC official recall · 08199

Rinnai Recalls Wall Furnaces Due to Carbon Monoxide Hazard

召回日期:2008-02-21官方最后发布:2014-05-23适用地区:美国
重要:以下安全事实保留 CPSC 官方英文原文,避免翻译改变含义。请通过右侧官方公告确认行动要求。

危险说明 Hazard

  • A gasket in the unit can fail, posing a risk of poisonous carbon monoxide gas leaking into the home.

受影响产品

Direct-Vent Wall Furnaces, Models RHFE 431 and RHFE 556
Units:About 52,000

官方描述 Description

The recall involves Rinnai EnergySaver Direct-Vent Wall Furnaces, Models RHFE 431 and RHFE 556. They are either natural gas or LP gas (propane) fueled. The following model numbers are included in the recall: Model RHFE-431 FAIII-N FAIII-P WTA-N WTA-P WTA-72B-N WTA-76B-N Model RHFE-556 FAIII-N FAIII-P WTA-N WTA-P The model number is printed on the top of the rating plate located on the right side of the unit. The recall includes only those units manufactured from February 2000 through December 2007. The manufacturing date code is the first four digits of the serial number, written as YY MM, and is located at the bottom of the rating plate.

事故与伤害 Incidents / Injuries

  • Rinnai has received 11 reports of carbon monoxide leaking from the furnace. No injuries have been reported.

官方补救措施 Remedy

  • Consumers should stop using the furnace immediately and contact the firm to arrange for the installation of a free repair kit.

消费者联系信息

For additional information, contact Rinnai toll-free at (866) 746-8344 anytime, or visit the firm's Web site at www.wallfurnacerecall.com

相关企业

制造商:Rinnai America Corp., of Peachtree City, Ga.

制造国家/地区:Japan

零售商:Wholesale distributors nationwide to contractors and dealers from February 2000 through December 2007 for between $1,600 and $1,900.