危险说明 Hazard

  • Fraying of wiring within the wiring harness can cause the juice dispenser's transformer to overheat, posing a fire hazard.

受影响产品

Quest Commercial Juice Dispensers
Units:About 14,000

官方描述 Description

The recalled commercial juice dispensers have two or four dispensing valves with an illuminated or opaque rounded front cover. Dispensers with serial numbers starting with the following characters are included in this recall: 62A0522JT to 62A0540JT 62E0416JT to 62E0441JT 62F0425JT to 62F0453JT 62F0502JT to 62F0553JT 62F0601JT to 62F0631JT 72A0107JT to 72A0148JT 72A0303JT to 72A0350JT 72B0149JT to 72B0151JT 72B0202JT to 72B0252JT 72B0301JT to 72B0351JT 72C0305JT to 72C0352JT 72C0402JT to 72C0413JT 72D0345JT to 72D0353JT 72D0402JT to 72D0413JT 72E0414JT to 72E0424JT 72A0202JT The serial number can be found on the inside of the front door of the dispenser.

事故与伤害 Incidents / Injuries

  • IMI Cornelius has received one report of a transformer smoldering and smoking. No injuries or property damage have been reported.

官方补救措施 Remedy

  • Customers should unplug the unit, open the door, and inspect the wire harness in the bottom left corner of the cabinet. If the colored wiring is cut or cracked (see photos), customers should immediately stop using the unit and contact IMI Cornelius. IMI Cornelius is contacting all customers directly to provide a free repair kit.

消费者联系信息

For additional information, call IMI Cornelius at (800) 344-3801 between 7:30 a.m. and 5 p.m. CT Monday through Friday, or visit the firm's Web site at www.cornelius.com

相关企业

制造商:IMI Cornelius, of Osseo, Minn.

制造国家/地区:United States

零售商:Commercial customers for installation in hospitality and other food service establishments nationwide from February 2001 through August 2006 for about $2,000 (2-flavor unit) or about $3,200 (4-flavor unit).