CPSC official recall · 18739

HD Supply Recalls Ceiling Fans Due to Impact Hazard (Recall Alert)

召回日期:2018-04-25官方最后发布:2018-04-25适用地区:美国
重要:以下安全事实保留 CPSC 官方英文原文,避免翻译改变含义。请通过右侧官方公告确认行动要求。

危险说明 Hazard

  • The brackets connected to the fan blades can break and allow the blades to fall, posing an impact hazard.

受影响产品

Seasons ceiling fans
Units:About 144,000

官方描述 Description

This recall involves Seasons-branded 52" five-blade ceiling fans. The recalled fans were sold in white, brass, bronze, and brushed nickel finishes and have zero, one, three or four lights. Model numbers 269702, 269712, 269714, 269716, 269718, 269808, 269810, 269812, 269816, 269818, 269820 and 269822 are included in this recall. The model number is printed on a label on top of the motor housing.

事故与伤害 Incidents / Injuries

  • HD Supply has received 13 reports of a bracket breaking and allowing a fan blade to fall, including one report of minor property damage. No injuries have been reported.

官方补救措施 Remedy

  • Consumers should immediately stop using the recalled fans and contact HD Supply to receive a free repair kit. HD Supply is contacting all known purchasers directly.

Options:Repair

消费者联系信息

HD Supply at 800-782-4154 from 6 a.m. to 5 p.m. PT Monday through Friday, email at FMWarrantySolutions@hdsupply.com or online at www.HDSupplySolutions.com and click on Resources and then on Recall Information for more information.

相关企业

制造商:Taishan Sigma, of China

制造国家/地区:China

进口商:HD Supply, of Atlanta, Ga.

经销商:HD Supply, of Atlanta, Ga.

零售商:HD Supply stores nationwide and online at www.HDSupplySolutions.com from March 2016 through February 2018 for between $60 and $140.