CPSC official recall · 24347

Head Rush Technologies Recalls TRUBLUE Speed Auto Belay Devices Due to Fall Hazard

召回日期:2024-08-22官方最后发布:2024-08-22适用地区:美国
重要:以下安全事实保留 CPSC 官方英文原文,避免翻译改变含义。请通过右侧官方公告确认行动要求。

危险说明 Hazard

  • The auto belay device backup brake can fail to activate, posing a fall hazard and risk of serious injury or death.

受影响产品

TRUBLUE Speed Auto Belay Devices
Units:About 220

官方描述 Description

This recall involves Head Rush Technologies TRUBLUE Speed Auto Belay Devices, 12.5m and 16m versions. The device enables climbers to safely descend after a speed climbing event. The device is gray with blue handles, the 12.5m version has black webbing handgrip above the carabiner, and the 16m version has blue webbing handgrip. The model TRUBLUE Speed TBSD150-20 and serial number are on a label located on the handle. The auto belay devices have a serial number within the serial number range: TBSD00098 through TBSD01180.

事故与伤害 Incidents / Injuries

  • The firm has received one incident report involving brake failure, causing the user to fall, resulting in a broken ankle.

官方补救措施 Remedy

  • Consumers should immediately stop using the recalled auto belay devices and contact Head Rush Technologies for a free inspection and repair. Head Rush Technologies is contacting all known purchasers directly.

Options:Repair

消费者联系信息

Head Rush Technologies collect at 720-565-6885 from 8:30 a.m. to 5 p.m. MT Monday through Friday, email at inf@headrushtech.com, or online at https://info.headrushtech.com/hubfs/Product_Recalls/2024_TRUBLUESpeed_Limited_Recall.pdf or www.headrushtech.com and click on the "Recall" banner for more information.

相关企业

制造商:Head Rush Technologies, of Louisville, Colorado

制造国家/地区:United States

零售商:Online at www.headrushtech.com from May 2017 through July 2021 for between $2,800 and $2,900.